Gel imaging NuGenius

Gel imaging NuGenius

NuGenius is a new generation, low cost, integrated system for DNA and protein analysis and gel documentation. Continuing the "Genius" range, the NuGenius features an integrated 7 inch touch screen and a built in processor running our new dedicated NuGenius software for image capture and editing.
A new ground breaking 5m pixel CCD camera gives exquisite pixel resolution and unrivalled sensitivity in its class. NuGenius uses an f/1.2 motor driven zoom lens to enable perfect imaging of any gel or blot size.

The maximum viewing area is 20 x 24cm which is very large for such a small, compact unit. Internal lighting includes a UV transilluminator option for working with DNA gels. Our new UV-Blue light converter screen allows imaging of all Safe dyes. A visible light converter option can quickly extend its use for working with visible gels and blots. Overhead LED white lighting is included as standard for easy sample positioning and focusing.

NuGenius is compatible with "safe dyes" such as SYBR® Gold, SYBR® Safe, GelGreen™ and many more as well as with visible light applications such as Coomassie blue and silver stain gels. NuGenius+ has been designed for stain free applications.

It has a modified camera enabling the user to expose for longer periods of time. Images are saved direct to USB memory stick for easy transfer to a PC or laptop.

Quickly generate quantitative data with GeneTools analysis software. 4 copies are included as standard. Extra copies can be requested at no extra charge.

NuGeniusNuGeniusNuGenius


Applications & Benefits
Compact darkroom with hinged doorSmall footprint taking up minimal laboratory bench space
5 million pixel cameraExceptional resolution for high quality images
Motor driven opticsEase of control
Can use a range of lightingVersatile - white light, blue light, UV
UV-visible light converter screen andEasy and safe imaging of DNA and protein gels
UV-blue light converter screen optionFull intuitive touch control of all functions
Touch screenTotal control over image quality
Image enhancements & annotationsSaves time by automating analysis of gels, colony plates and blots
GeneTools analysis softwareSmall footprint taking up minimal laboratory bench space


Ordering Information
NuGenius System
5MP camera (0,4 inch sensor) with motor driven zoom lens f1.2 With epi white lights for sample positioning.
1 UV filter 572-630nm / UV032 /
4 copies of GeneTools.
Max image size 20 x 24cm.
Transilluminator & converter screens not supplied
please select required source from list below.

Camera: 5MP camera , 0,4 inch sensor, 12 / 16 bit
Lenses: Motor driven zoom lens 8-48mm, f1.2
Image size: Max. 20 x 24cm
On Board Computer: with7 inch touch screen
NUGENIUSPlease contact us
NuGenius System plus
5MP camera (0,66 inch sensor) with motor driven zoom lens f1.4 With epi white lights for sample positioning.
1 UV filter 572 - 635nm / UV06
4 copies of GeneTools.
Max image size 20 x 24cm.
Transilluminator & converter screens not supplied
please select required source from list below.

Camera: 5MP camera , 0,66 inch sensor, 12 bit camera/ 16 bit picture
Lenses: Motor driven zoom lens 11-69mm, f1.4
Imagesize: Max. 20 x 24cm
On Board Computer: with7 inch touch screen
NUGENIUS PLUSPlease contact us
Filter for NuGenius
572 - 630nm / UV032 / IncludedFILTUV-58316,00 €
515 - 599 nm / SW032FILTSP-58520,00 €
Filter for NuGenius plus
572 - 635nm / UV06 / for stain free imaging included with instrument purchase FILTUV06-58Please contact us
Lighting
Overhead White Light
Included in every NuGenius Box is an integral white LED EPI lighting system for the viewing of visible light blots, sample positioning and when imaging colorimetric markers on Western blots.
Converter Screens
Included in every NuGenius Box is an integral white LED EPI lighting system for the viewing of visible light blots, sample positioning and when imaging colorimetric markers on Western blots.
Blue Light converter ( for use with UV Transilluminator)CONVERTBLUE-2126399,00 €
Visible light converter ( for use with UV Transilluminator)GE-CONVERT5133,00 €
UV Transilluminator slide out
Transilluminator (20 x 20cm; 365nm) 230V, 50Hz with runnersGE-2020L-E844,00 €
Transilluminator (20 x 24cm; 365nm) 230V, 50Hz with runnersGE-2024L-E1.164,00 €
Transilluminator (20 x 20cm; 302nm) 230V, 50Hz with runnersGE-2020M-E898,00 €
Transilluminator (20 x 24cm; 302nm) 230V, 50Hz with runnersGE-2024M-E1.185,00 €
Transilluminator (20 x 20cm; 254nm) 230V, 50Hz with runnersGE-2020S-E855,00 €
Transilluminator (20 x 24cm; 254nm) 230V, 50Hz with runnersGE-2024S-E1.142,00 €
Replacement Tubes
Short wave tube, 8W, 254nmSWT823,00 €
Medium wave, 8W, 302nmMWT830,00 €
Longwave 8W, 365nmLWT824,00 €
UV Protection
Safety screenUV-Screen345,00 €
PC
No PC or Touch Panel PC is supplied, please select from list below
PC-STDPC-STD1.320,00 €
Software
GeneTools Software (4 copies)GeneTools-Software-4inclusive
GeneDirectory Database softwareGENEDIRECTORY-DB1.642,00 €
Options
Neutral field screens for UV neutral fielding (1 blue, 1 frosted).GE-NFS30,00 €
Printer
Any printer with appropriate Windows drivers can be attached to the GeneGnome. We recommend a thermal A6 printer such as Sony or Mitsubishi. These USB printers will 'plug and play' with the GeneGnome and require minimal setup. They will print hard copies of blots in under 5 seconds on long life glossy thermal paper to give photographic quality images.
Canon Selphy CP1200NuGen-PrintPlease contact us
Canon KP-108IN ink and paper setNuGen-PaperPlease contact us

Technical Specification

NuGenius

Camera5 million pixel
Sensor0,4 inch
Bit depth12 /16 bit
Greyscale0-65,536
Dynamic range3.6 / 4.8 (extended)
Lens8 - 48mm f/1.2
Viewing area20 x 24cm
Illumination
Slim transilluminator 20 x 24cmOption
Blue converter screen 21 x 26cmOption
Visible light converterOption
White epiYes
Software
7 inch touch screenYes
Image captureYes-on board computer
GeneTools analysisYes ( 4 copies included)
GeneDirectoryOption
PrinterOption
Paper and inkThermal paper
Dimensions
H x W x D cms75 x 31 x 45
Weight

NuGenius +

Camera5 million pixel
Sensor0,66 inch
Bit depth12/16 bit
Greyscale0-65,536
Dynamic range3.6 / 4.8 (extended)
Lens11.5 - 69mm f/1.4
Viewing area20 x 24cm
Illumination
Slim transilluminator 20 x 24cmOption
Blue converter screen 21 x 26cmOption
Visible light converterOption
White epiYes
Software
7 inch touch screenYes
Image captureYes-on board computer
GeneTools analysisYes ( 4 copies included)
GeneDirectoryOption
PrinterOption
Paper and inkThermal paper
Dimensions
H x W x D cms75 x 31 x 45
Weight
Applications & Benefits
Ordering Information
Technical Specifications




Alternative content

Get Adobe Flash player



Downloads
PDF-FileNuGenius Brochure
Brochure
0.7 MB


Most Wanted
U:Genius3U:Genius3
UltraSlim LED TransilluminatorsUltraSlim LED Transilluminators
AccuRuler 100bpLadderAccuRuler 100bpLadder
GeneDirectoryGeneDirectory
ChemiluminescenceChemiluminescence
UltraSafeBlueUltraSafeBlue
Chemiluminescence and FluorescenceChemiluminescence and Fluorescence
FluorescenceFluorescence
AccuRuler 1kbLadderAccuRuler 1kbLadder
ProteomicsProteomics
Imprint | Contactform