Gel imaging NuGenius NuGenius is a new generation, low cost, integrated system for DNA and protein analysis and gel documentation. Continuing the "Genius" range, the NuGenius features an integrated 7 inch touch screen and a built in processor running our new dedicated NuGenius software for image capture and editing.
A new ground breaking 5m pixel CCD camera gives exquisite pixel resolution and unrivalled sensitivity in its class. NuGenius uses an f/1.2 motor driven zoom lens to enable perfect imaging of any gel or blot size.
The maximum viewing area is 20 x 24cm which is very large for such a small, compact unit. Internal lighting includes a UV transilluminator option for working with DNA gels. Our new UV-Blue light converter screen allows imaging of all Safe dyes. A visible light converter option can quickly extend its use for working with visible gels and blots. Overhead LED white lighting is included as standard for easy sample positioning and focusing.
NuGenius is compatible with "safe dyes" such as SYBR® Gold, SYBR® Safe, GelGreen™ and many more as well as with visible light applications such as Coomassie blue and silver stain gels. NuGenius+ has been designed for stain free applications.
It has a modified camera enabling the user to expose for longer periods of time. Images are saved direct to USB memory stick for easy transfer to a PC or laptop.
Quickly generate quantitative data with GeneTools analysis software. 4 copies are included as standard. Extra copies can be requested at no extra charge.
Compact darkroom with hinged door | Small footprint taking up minimal laboratory bench space | 5 million pixel camera | Exceptional resolution for high quality images | Motor driven optics | Ease of control | Can use a range of lighting | Versatile - white light, blue light, UV | UV-visible light converter screen and | Easy and safe imaging of DNA and protein gels | UV-blue light converter screen option | Full intuitive touch control of all functions | Touch screen | Total control over image quality | Image enhancements & annotations | Saves time by automating analysis of gels, colony plates and blots | GeneTools analysis software | Small footprint taking up minimal laboratory bench space |

NuGenius System 5MP camera (0,4 inch sensor) with motor driven zoom lens f1.2 With epi white lights for sample positioning.
1 UV filter 572-630nm / UV032 /
4 copies of GeneTools.
Max image size 20 x 24cm.
Transilluminator & converter screens not supplied
please select required source from list below.
Camera: 5MP camera , 0,4 inch sensor, 12 / 16 bit Lenses: Motor driven zoom lens 8-48mm, f1.2 Image size: Max. 20 x 24cm On Board Computer: with7 inch touch screen | NUGENIUS | Please contact us |
NuGenius System plus 5MP camera (0,66 inch sensor) with motor driven zoom lens f1.4 With epi white lights for sample positioning.
1 UV filter 572 - 635nm / UV06
4 copies of GeneTools.
Max image size 20 x 24cm.
Transilluminator & converter screens not supplied
please select required source from list below.
Camera: 5MP camera , 0,66 inch sensor, 12 bit camera/ 16 bit picture Lenses: Motor driven zoom lens 11-69mm, f1.4 Imagesize: Max. 20 x 24cm On Board Computer: with7 inch touch screen
| NUGENIUS PLUS | Please contact us |
572 - 630nm / UV032 / Included | FILTUV-58 | 316,00 € |
515 - 599 nm / SW032 | FILTSP-58 | 520,00 € |
572 - 635nm / UV06 / for stain free imaging included with instrument purchase
| FILTUV06-58 | Please contact us |
Overhead White Light | Included in every NuGenius Box is an integral white LED EPI lighting system for the viewing of visible light blots, sample positioning and when imaging colorimetric markers on Western blots. |
Converter Screens | Included in every NuGenius Box is an integral white LED EPI lighting system for the viewing of visible light blots, sample positioning and when imaging colorimetric markers on Western blots. |
Blue Light converter ( for use with UV Transilluminator) | CONVERTBLUE-2126 | 399,00 € |
Visible light converter ( for use with UV Transilluminator) | GE-CONVERT5 | 133,00 € |
UV Transilluminator slide out |
Short wave tube, 8W, 254nm | SWT8 | 23,00 € |
Medium wave, 8W, 302nm | MWT8 | 30,00 € |
Longwave 8W, 365nm | LWT8 | 24,00 € |
Safety screen | UV-Screen | 345,00 € |
PC | No PC or Touch Panel PC is supplied, please select from list below |
Neutral field screens for UV neutral fielding (1 blue, 1 frosted). | GE-NFS | 30,00 € |
Printer | Any printer with appropriate Windows drivers can be attached to the GeneGnome. We recommend a thermal A6 printer such as Sony or Mitsubishi. These USB printers will 'plug and play' with the GeneGnome and require minimal setup. They will print hard copies of blots in under 5 seconds on long life glossy thermal paper to give photographic quality images. |

| NuGenius | Camera | 5 million pixel | Sensor | 0,4 inch | Bit depth | 12 /16 bit | Greyscale | 0-65,536 | Dynamic range | 3.6 / 4.8 (extended) | Lens | 8 - 48mm f/1.2 | Viewing area | 20 x 24cm | Illumination | Slim transilluminator 20 x 24cm | Option | Blue converter screen 21 x 26cm | Option | Visible light converter | Option | White epi | Yes | Software | 7 inch touch screen | Yes | Image capture | Yes-on board computer | GeneTools analysis | Yes ( 4 copies included) | GeneDirectory | Option | Printer | Option | Paper and ink | Thermal paper | Dimensions | H x W x D cms | 75 x 31 x 45 | Weight |
| | NuGenius + | Camera | 5 million pixel | Sensor | 0,66 inch | Bit depth | 12/16 bit | Greyscale | 0-65,536 | Dynamic range | 3.6 / 4.8 (extended) | Lens | 11.5 - 69mm f/1.4 | Viewing area | 20 x 24cm | Illumination | Slim transilluminator 20 x 24cm | Option | Blue converter screen 21 x 26cm | Option | Visible light converter | Option | White epi | Yes | Software | 7 inch touch screen | Yes | Image capture | Yes-on board computer | GeneTools analysis | Yes ( 4 copies included) | GeneDirectory | Option | Printer | Option | Paper and ink | Thermal paper | Dimensions | H x W x D cms | 75 x 31 x 45 | Weight |
|
 |
|
 
 
 

|