Easily convert your NanoPhotometer® C40 cuvette spectrophotometer into a nanovolume spectrophotometer with the sub-micro liter cell from Implen. With as little as 0.3 µ:l sample volume, samples can now be virtually diluted and analyzed directly. There are a variety of path-lengths that can be utilized with the sub-microliter cell to provide virtual sample dilution including 2 mm, 1 mm, 0.2 mm, 0.1 mm and 0.04 mm.

How it Works

How it Works

Sample Compression Technology™

  • Dual Absorption™ of light for ultra sensitivity at low concentrations with minimal sample volumes of 0.3 µl

  • Reliable solution for small volume protein measurements due to independence of sample surface tension; No issues of column formation with low surface tension samples

  • Reproducible results due to contained micro sample environment; Applications expanded to analytes in volatile solvents, such as drugs or other challenging sample types

  • No recalibration or maintenance as optical components and pathlengths are fixed without drift; Quartz sample surface is scratch resistant, inert, and does not require regular surface reconditioning



Applications & Benefits
Can be used with every existing scanning photometer holding standard cuvettes
Low concentrations with minimal sample volumes of 0.3 ?l
Reproducible results due to contained micro sample environment
Reliable solution for small volume protein measurements
No recalibration or maintenance
Does not require regular surface reconditioning


Ordering Information
Submicroliter Cell for the NanoPhotometer? C40 for samples with 0.3 ?l to 2 ?l volume, incl. dilution lid 10 (path length 1 mm) and lid 50 (path length 0.2 mm)C40-SMC13.000,00 €
2 mm lid for the NanoPhotometer? Submicroliter Cell, Dilution Factor 5, sample volume 3.5 - 5 ?lC40-SMC-L21400,00 €
1 mm lid for the NanoPhotometer? Submicroliter Cell, Dilution Factor 10, sample volume 1 - 3 ?lC40-SMC-L11400,00 €
0.2 mm lid for the NanoPhotometer? Submicroliter Cell, Dilution Factor 50, sample volume 0.3 - 2 ?lC40-SMC-L021400,00 €
0.1 mm lid for the NanoPhotometer? Submicroliter Cell, Dilution Factor 100, sample volume 0.3 - 2 ?lC40-SMC-L011400,00 €
0.04 mm lid for the NanoPhotometer? Submicroliter Cell, Dilution Factor 250, sample volume 0.3 - 2 ?lC40-SMC-L0041400,00 €

Technical Specification
Volume 0.3 ?l to 2 ?l volume,
Lid 10path length 1.0 mm
Lid 50path length 0.2 mm
2.0 mm lidDilution Factor 5,
1.0 mm lidDilution Factor 10,
0.2 mm lidDilution Factor 50
0.1 mm lidDilution Factor 100
0.04 mm lidDilution Factor 250
Applications & Benefits
Ordering Information
Technical Specifications






Most Wanted
C40C40
N60N60
Compare ModelsCompare Models
N50N50
IQ-Q PackageIQ-Q Package
NP80NP80
DiluCellDiluCell
Sub Microliter CellSub Microliter Cell
NanoPotometerNanoPotometer
OD600 Dilu PhotometerOD600 Dilu Photometer
Imprint